BD Biosciences/CD8 (Leu™-2a) PE/20 µL/340046
产品编号:340046
市  场 价:¥0.00
场      地:美国(厂家直采)
产品分类: 蛋白类>多肽>多肽合成>
联系QQ:1570468124
电话号码:4000-520-616
邮      箱: info@ebiomall.com
美  元  价:待定
品      牌: BD Biosciences
公      司:BD Biosciences,Inc.
公司分类:
BD Biosciences/CD8 (Leu™-2a) PE/20 µL/340046
商品介绍
Product DetailsRecommended AssayReferences

Description

Becton Dickinson Immunocytometry Systems (BDIS) CD8 (Leu™-2a) phycoerythrin (PE) is a single-color direct immunofluorescence reagent for enumerating percentages of mature human suppressor/cytotoxic (CD8+) lymphocytes in erythrocyte-lysed whole blood (LWB) or peripheral blood mononuclear cell (PBMC) suspensions.

Preparation and Storage

1. For in vitro diagnostic use.

2. When stored at 2° to 8°C, the antibody reagent is stable until the expiration date shown on the label. Do not use after the expiration date.

3. The antibody reagent should not be frozen or exposed to direct light during storage or during incubation with cells. Keep the reagent vial dry.

4. Alteration in the appearance of the reagent, such as precipitation or discoloration, indicates instability or deterioration. In such cases, the reagent should not be used.

5. The antibody reagents contain sodium azide as a preservative; however, care should be taken to avoid microbial contamination, which may cause erroneous results.

  1. Antel J, Bania M, Noronha A, Neely S. Defective suppressor cell function mediated by T8+ cell lines from patients with progressive multiple sclerosis. J Immunol. 1986;137:3436-3439.

  2. Bernard A, Boumsell L, Hill C. Joint report of the First International Workshop on Human Leucocyte Differentiation Antigens by the investigators of the participating laboratories: T2 protocol. In: Bernard A, Boumsell L, Dausset J, Milstein C, Schlossman S, eds. Leucocyte Typing. 1984:25-60.

  3. Bishop G, Hall B, Duggin G, et al. Immunopathology of renal allograft refection analyzed with monoclonal antibodies to mononuclear cell markers. Kidney Internat. 1986;29:708-717.

  4. Centers for Disease Control. Guidelines for the performance of CD4+ T-cell determination in persons with human immunodeficiency virus infection. MMWR. 1992;41(No. RR-8):1-17.

  5. Evans RL, Wall DW, Platsoucas CD, et al. Thymus dependent membrane antigens in man: inhibition of cellmediated lympholysis by monoclonal antibodies to the TH2 antigen. Proc Natl Acad Sci USA. 1981;78:544-548.

  6. Gallagher P, Fazekas de St. Groth B, Miller J. CD4 and CD8 molecules can physically associate with the same T-cell receptor. Proc Natl Acad Sci USA. 1989;86:10044-10048.

  7. Giorgi J, Hultin L. Lymphocyte subset alterations and immunophenotyping by flow cytometry in HIV disease. Clin Immunol Newslett. 1990;10:55-62.

  8. Giorgi J. Lymphocyte subset measurements: significance in clinical medicine. In: Rose N, Friedman H, Fahey J, eds. Manual of Clinical Laboratory Immunology. 1986:236-246.

  9. Gratama J, Naipal A, Oljans P, et al. T lymphocyte repopulation and differentiation after bone marrow transplantation. Early shifts in the ratio between T4+ and T8+ T lymphocytes correlate with the occurrence of acute graft-versus-host disease. Blood. 1984;63(6):1416-1423.

  10. Jackson A, Warner N. Preparation, staining, and analysis by flow cytometry of peripheral blood leukocytes. In: Rose N, Friedman H, Fahey J, eds. Manual of Clinical Laboratory Immunology. 1986:226-235.

  11. Jackson A. Basic phenotyping of lymphocytes: selection and testing of reagents and interpretation of data. Clin Immunol Newslett. 1990;10:43-55.

  12. Lanier LL, Le AM, Phillips JH, Warner NL, Babcock GF. Subpopulations of human natural killer cells defined by expression of the Leu-7 (HNK-1) and Leu-11 (NK-15) antigens. J Immunol. 1983;131:1789-1796.

  13. Ledbetter J, Evans R, Lipinski M, et al. Evolutionary conservation of surface molecules that distinguish T lymphocyte helper/inducer and T cytotoxic/suppressor subpopulations in mouse and man. J Exp Med. 1981;153:310-323.

  14. Mishell B, Shiigi S, Henry C, et al. Preparation of mouse cell suspensions. In: Mishell B, Shiigi S, eds. Selected Methods in Cellular Immunology. New York: WH Freeman and Co; 1980:16-17.

  15. National Committee for Clinical Laboratory Standards. Clinical Applications of Flow Cytometry: Quality Assurance and Immunophenotyping of Peripheral Blood Lymphocytes; Tentative Guideline (H42-T). 1992

  16. National Committee for Clinical Laboratory Standards. Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture (H3-A3). 1991

  17. Prince H, Hirji K, Waldbeser L, Plaeger-Marshall S, Kleinman S, Lanier L. Influence of racial background on the distribution of T cell subsets and Leu-11–positive lymphocytes in healthy blood donors. Diag Immunol. 1985;3:33-37.

  18. Reichert T, DeBruyère M, Deneys V, et al. Lymphocyte subset reference ranges in adult Caucasians. Clin Immunol Immunopath. 1991;60:190-208.

  19. Rudd C, Burgess K, Barber E, Schlossman S. Monoclonal antibodies to the CD4 and CD8 antigens precipitate variable amounts of CD4/CD8-associated p56lck activity. In: Knapp W, Dörken B, Gilks WR, et al, eds. Leucocyte Typing IV: White Cell Differentiation Antigens. New York, NY: Oxford University Press; 1989:326-327.

  20. Schmidt R. Monoclonal antibodies for diagnosis of immunodeficiencies. Blut. 1989;59:200–206.

  21. Wolde-Mariam W, Peter J. Recent diagnostic advances in cellular immunology. Diagnost Med. 1984;7:25-32.

品牌介绍

BD是世界上最大的生产和销售医疗设备、医疗系统和试剂的医疗技术公司之一。致力于提高全世界人类的健康水平。BD专注于改进药物治疗,提高传染性疾病诊断的质量和速度,推进新型药物和疫苗的研究与发现。公司于1897年在纽约成立,总部位于美国新泽西州的富兰克林湖,业务可分为BD医疗、BD诊断、BD生物科学三大类,生产销售包括医用耗材、实验室仪器、抗体、试剂、诊断等产品。

自营商城图标
厂家直采
全球直采 正品优价
正品保障图标
正品保障
厂家直发 有线跟踪
解放采购图标
正规清关
CIF100%正规报关,提供发票
及时交付图标
及时交付
限时必达 不达必赔