请使用支持JavaScript的浏览器!
主营:医疗设备、医疗耗材、实验仪器、抗体、试剂、诊断等产品
℡ 4000-520-616
℡ 4000-520-616
BD Biosciences/CD3 FITC/ CD8 PE/CD45 PerCP/CD4 APC/20 µL/340499
产品编号:340499
市  场 价:¥0.00
场      地:美国(厂家直采)
产品分类: 蛋白类>多肽>多肽合成>
联系QQ:1570468124
电话号码:4000-520-616
邮      箱: info@ebiomall.com
美  元  价:待定
品      牌: BD Biosciences
公      司:BD Biosciences,Inc.
公司分类:
BD Biosciences/CD3 FITC/ CD8 PE/CD45 PerCP/CD4 APC/20 µL/340499
商品介绍
Product DetailsRecommended AssayReferences

Description

BD Multitest CD3 fluorescein isothiocyanate (FITC)/CD8 phycoerythrin (PE)/CD45 peridinin chlorophyll protein (PerCP)/CD4 allophycocyanin (APC) is a four-color direct immunofluorescence reagent for identifying and determining the percentages and absolute counts of mature human T lymphocytes (CD3+), suppressor/cytotoxic (CD3+CD8+) T-lymphocyte subsets, and helper/inducer (CD3+CD4+) T-lymphocyte subsets in erythrocyte-lysed whole blood. When used with BD Trucount™ absolute count tubes, these populations can be enumerated from a single tube.

Contents

SpecificityCloneFormatIsotypeEntrez Gene ID
CD4SK3 (also known as Leu3a)APCIgG1, κ920
CD3SK7 (also known as Leu-4)FITCIgG1, κ916
CD8SK1PEIgG1, κ925
CD452D1PerCPIgG1, κ
Preparation and Storage

• Store the reagent at 2–8°C. Do not use after the expiration date shown on the label.

• Do not freeze the reagent or expose it to direct light during storage or incubation with cells. Keep the reagent vial dry.

• Store BD Trucount tubes in their original foil pouch at 2–25°C. To avoid potential condensation, open the pouch only after it has reached room temperature and carefully reseal the pouch immediately after removing a tube. Examine the desiccant each time you open the pouch. If the desiccant has turned from blue to lavender, discard the remaining tubes. Use tubes within 1 hour after removal from the foil pouch and do not use beyond the expiration date indicated on the packaging.

  1. How to Define and Determine Reference Intervals in the Clinical Laboratory; Approved Guideline–Second Edition. Wayne, PA: National Committee for Clinical Laboratory Standards; 2000. NCCLS document C28-A2.

  2. Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture–Fourth Edition; Approved Standard. Wayne, PA: National Committee for Clinical Laboratory Standards; 1998. NCCLS document H3-A4.

  3. Protection of Laboratory Workers from Occupationally Acquired Infections; Approved Guideline—Third Edition. Wayne, PA: Clinical and Laboratory Standards Institute; 2005. CLSI document M29-A3.

  4. Anderson P, Blue M-L, Morimoto C, Schlossman SF. Cross-linking of T3 (CD3) with T4 (CD4) enhances the proliferation of resting T lymphocytes. J Immunol. 1987;139:678-682.

  5. Angadi CV. Lack of Leu-3a epitope on T-helper (CD4) lymphocytes. J Clin Lab Anal. 1990;4:193-195.

  6. Antel J, Bania M, Noronha A, Neely S. Defective suppressor cell function mediated by T8+ cell lines from patients with progressive multiple sclerosis. J Immunol. 1986;137:3436-3439.

  7. Bernard A, Boumsell L, Hill C. Joint report of the first international workshop on human leucocyte differentiation antigens by the investigators of the participating laboratories. Leucocyte Typing. New York, NY: Springer-Verlag; 1984:9-108.

  8. Brenner MB, McClean J, Dialynas DP, et al. Identification of a putative second T cell receptor. Nature. 1986;322:145-49.

  9. Centers for Disease Control. 1997 Revised guidelines for performing CD4+ T-cell determinations in persons with human immunodeficiency virus (HIV). MMWR. 1997;46(No. RR-2):1-29.

  10. Centers for Disease Control. Update: universal precautions for prevention of transmission of human immunodeficiency virus, hepatitis B virus, and other bloodborne pathogens in health-care settings. MMWR. 1988;37:377-388.

  11. Clevers H, Alarcón B, Wileman T, Terhorst C. The T cell receptor/CD3 complex: a dynamic protein ensemble. Annu Rev Immunol. 1988;6:629-662.

  12. Cobbold SP, Hale G, Waldmann H. Non-lineage, LFA-1 family, and leucocyte common antigens: new and previously defined clusters. In: McMichael AJ, eds. Leucocyte Typing III: White Cell Differentiation Antigens. New York, NY: Oxford University Press; 1987:788-803.

  13. Cohen S, Weetman A. Activated interstitial and intraepithelial thyroid lymphocytes in autoimmune thyroid disease. Acta Endocr. 1988;119:161-166.

  14. Dalgleish AG, Beverley PCL, Clapham PR, Crawford DH, Greaves MF, Weiss RA. The CD4 (T4) antigen is an essential component of the receptor for the AIDS retrovirus. Nature. 1984;312:763-767.

  15. Eichmann K, Jönsson J-I, Falk I, Emmrich F. Effective activation of resting mouse T lymphocytes by cross-linking submitogenic concentrations of the T cell antigen receptor with either Lyt-2 or L3T4. Eur J Immunol. 1987;17:643-650.

  16. Evans RL, Wall DW, Platsoucas CD, et al. Thymus-dependent membrane antigens in man: inhibition of cell-mediated lympholysis by monoclonal antibodies to the TH2 antigen. Proc Natl Acad Sci USA. 1981;78:544-548.

  17. Foucar K, Goeken J. Clinical application of immunologic techniques to the diagnosis of lymphoproliferative and immunodeficiency disorders. Lab Medicine. 1982;13:403.

  18. Gallagher PF, Fazekas de St. Groth B, Miller JFAP. CD4 and CD8 molecules can physically associate with the same T-cell receptor. Proc Natl Acad Sci USA. 1989;86:10044-10048.

  19. Giorgi J. Lymphocyte subset measurements: significance in clinical medicine. In: Rose N, Friedman H, Fahey J, eds. Manual of Clinical Laboratory Immunology. Washington, DC: American Society for Microbiology; 1986:236-246.

  20. Giorgi JV, Hultin LE. Lymphocyte subset alterations and immunophenotyping by flow cytometry in HIV disease. Clin Immunol Newslett. 1990;10:55-61.

  21. Haynes BF. Summary of T-cell studies performed during the Second International Workshop and Conference on Human Leukocyte Differentiation Antigens. In: Reinherz EL, Haynes BF, Nadler LM, Bernstein ID, eds. Leukocyte Typing II: Human T Lymphocytes. New York, NY: Springer-Verlag; 1986;1:3-30.

  22. Jackson A, Warner N. Preparation, staining, and analysis by flow cytometry of peripheral blood leukocytes. In: Rose N, Friedman H, Fahey J, eds. Manual of Clinical Laboratory Immunology. Washington, DC: American Society for Microbiology; 1986:226-235.

  23. Kan EAR, Wang CY, Wang LC, Evans RL. Noncovalently bonded subunits of 22 and 28 kd are rapidly internalized by T cells reacted with Anti–Leu-4 antibody. J Immunol. 1983;131:536-539.

  24. Knowles RW. Immunochemical analysis of the T-cell– specific antigens. In: Reinherz EL, Haynes BF, Nadler LM, Bernstein ID, eds. Leukocyte Typing II: Human T Lymphocytes. New York, NY: Springer-Verlag; 1986;1:259- 288.

  25. Landay A, Ohlsson-Wilhelm B, Giorgi J. Application of flow cytometry to the study of HIV infection. AIDS. 1990;4:479-497.

  26. Lanier LL, Le AM, Phillips JH, Warner NL, Babcock GF. Subpopulations of human natural killer cells defined by expression of the Leu-7 (HNK-1) and Leu-11 (NK-15) antigens. J Immunol. 1983;131:1789-1796.

  27. Maddon PJ, Dalgleish AG, McDougal JS, Clapham PR, Weiss RA, Axel R. The T4 gene encodes the AIDS virus receptor and is expressed in the immune system and the brain. Cell. 1986;47:333-348.

  28. Moebius U. Cluster report: CD8. In: Knapp W, Dörken B, Gilks WR, et al., eds. Leucocyte Typing IV: White Cell Differentiation Antigens. New York, NY: Oxford University Press Inc; 1989:342-343.

  29. Nicholson J, Kidd P, Mandy F, Livnat D, Kagan J. Three-color supplement to the NIAID DAIDS guideline for flow cytometric immunophenotyping. Cytometry. 1996;26:227- 230.

  30. Nicholson J. Use of flow cytometry in the evaluation and diagnosis of primary and secondary immunodeficiency diseases. Arch Pathol Lab Med. 1989;113:598-605.

  31. Nicholson JKA, Hubbard M, Jones BM. Use of CD45 fluorescence and side-scatter characteristics for gating lymphocytes when using the whole blood lysis procedure and flow cytometry. Cytometry. 1996;26: 16-21.

  32. Nicholson JKA, Jones BM, Hubbard M. CD4 T-lymphocyte determinations on whole blood specimens using a single-tube three-color assay. Cytometry. 1993;14:685-689.

  33. Organizing Committee of the Fourth International Workshop on Human Leucocyte Differentiation Antigens. Appendix A: CD guide. In: Knapp W, Dörken B, Gilks WR, et al, eds. Leucocyte Typing IV: White Cell Differentiation Antigens. 1989:1074-1093.

  34. Prince H, Hirji K, Waldbeser L, Plaeger-Marshall S, Kleinman S, Lanier L. Influence of racial background on the distribution of T cell subsets and Leu-11-positive lymphocytes in healthy blood donors. Diag Immunol. 1985;3:33-37.

  35. Rudd CE, Burgess KE, Barber EK, Schlossman SF. Monoclonal antibodies to the CD4 and CD8 antigens precipitate variable amounts of CD4/CD8-associated p56lck activity. In: Knapp W, Dörken B, Gilks WR, et al, eds. Leucocyte Typing IV: White Cell Differentiation Antigens. New York, NY: Oxford University Press; 1989:326-327.

  36. Schmidt R. Monoclonal antibodies for diagnosis of immunodeficiencies. Blut. 1989;59:200–206.

  37. Schwinzer R. Cluster report: CD45/CD45R. In: Knapp W, Dörken B, Gilks WR, et al, eds. Leucocyte Typing IV: White Cell Differentiation Antigens. New York, NY: Oxford University Press Inc; 1989:628-634.

  38. Smolen J, Chused T, Leiserson W, Reeves J, Alling D, Steinberg A. Heterogeneity of immunoregulatory T-cell subsets in systemic lupus erythematosus. Am J Med. 1982;72:783-790.

  39. van Dongen JJM, Krissansen GW, Wolvers-Tettero ILM, et al. Cytoplasmic expression of the CD3 antigen as a diagnostic marker for immature T-cell malignancies. Blood. 1988;71:603-612.

  40. Villanova, PA: National Committee for Clinical Laboratory Standards; Clinical Applications of Flow Cytometry: Immunophenotyping of Leukemic Cells; Approved Guideline. Villanova, PA: Natinal Committee for Clinical Laboratory Standards; 1998. H43-A.

  41. Wood GS, Warner NL, Warnke RA. Anti–Leu-3/T4 antibodies react with cells of monocyte/macrophage and Langerhans lineage. J Immunol. 1983;131:212-216.

品牌介绍

BD是世界上最大的生产和销售医疗设备、医疗系统和试剂的医疗技术公司之一。致力于提高全世界人类的健康水平。BD专注于改进药物治疗,提高传染性疾病诊断的质量和速度,推进新型药物和疫苗的研究与发现。公司于1897年在纽约成立,总部位于美国新泽西州的富兰克林湖,业务可分为BD医疗、BD诊断、BD生物科学三大类,生产销售包括医用耗材、实验室仪器、抗体、试剂、诊断等产品。

自营商城图标
厂家直采
全球直采 正品优价
正品保障图标
正品保障
厂家直发 有线跟踪
解放采购图标
正规清关
CIF100%正规报关,提供发票
及时交付图标
及时交付
限时必达 不达必赔